2 Years Single Gas Detector

Overview:
As the world’s most popular and widely used zero-maintenance gas detector, the GasAlertClip Extreme offers continuous, reliable protection. Available in two year or three year versions, this single gas detector requires no calibration, sensor replacement, battery replacement or battery charging. Compatible with the MicroDock II automatic test system, the simplicity of the GasAlertClip Extreme combined with minimal training requirements and negligible maintenance costs, make the GasAlertClip Extreme one of the most cost-effective PPE solutions for facility workers and on-site contractors.

Product Description

Main Features:

Durable, reliable and easy to use with no downtime
Record keeping is accurate and easy with automatic event logging
Exceptionally low cost of ownership
User-selectable alarm setpoints (5/10 or 10/15) on GA24XT-H510 model
Compact and lightweight design makes it comfortable to wear
Water-resistant
Compatible with BW MicroDock II automatic test station
Full function self-test of sensor, battery status, circuit integrity and audible/visual alarms
Bright wide-angled visual alarm bars
Built-in concussion-proof boot
Large confidence LCD displays life remaining in months, days and hours
Displays peak alarm exposures encountered on demand
User-activated daily self-test
Internal vibrating alarm for high noise environments
Records and transmits gas alarm events
User-selectable alarm setpoints (5/10 or 10/15) now available on GA24XT-H510 model

Specifications :

GasAlertClip Extreme Specifications:
Size 1.1 x 2.0 x 3.2 in. / 2.8 x 5.0 x 8.1 cm
Weight 2.7 oz. / 76 g
Temperature H2S: -40 to +122°F / -40 to +50°C
CO: -22 to +122°F / -30 to +50°C
SO2: -22 to +122°F / -30 to +50°C
O2: -4 to +122°F / -20 to +50°C
Humidity 5% – 95% RH (non-condensing)
Alarms – Visual, vibrating, audible (95dB)
– Low, High
Tests Full function self-test on activation and every 20 hours, and automatic battery test every 2 hours
Typical battery life Two years (H2S, CO, SO2 or O2) or three years (H2S or CO)
Warranty 2 or 3 years from activation (given normal operation), plus 1 year shelf life

Sensor Specifications:
Gas Measuring Range Low Alarm Level1 High Alarm Level1
2 or 3 year detector
H2S 0 -100 ppm 10 ppm 15 ppm
CO 0 – 300 ppm 35 ppm (30 ppm UK/EU) 200 ppm
2 year detector only
SO2 0 – 100 ppm 5 ppm 10 ppm
O2 0 – 30.0 % by vol. 19.5 % 23.5 %

Product Features

Size 1.1 x 2.0 x 3.2 in. / 2.8 x 5.0 x 8.1 cm
Weight 2.7 oz. / 76 g
Temperature H2S: -40 to +122°F / -40 to +50°C CO: -22 to +122°F / -30 to +50°C SO2: -22 to +122°F / -30 to +50°C O2: -4 to +122°F / -20 to +50°C
Humidity 5% - 95% RH (non-condensing)
Alarms - Visual, vibrating, audible (95dB) - Low, High
Tests Full function self-test on activation and every 20 hours, and automatic battery test every 2 hours
Typical battery life Two years (H2S, CO, SO2 or O2) or three years (H2S or CO)